     spec  - module to perform spectral  decomposition  of  input
     time data into descrete amplitude or phase spectra by either
     a descrete Fourier transform or Maximum Entropy Method.


SYNOPSIS

     spec [ -Nntap ] [ -Ootap ] [ -Sstap ] [ -Fftap ] [ -nsins  ]
     [  -neine  ]  [  -rsirs ] [ -reire ] [ -siwst ] [ -eiwed ] [
     -fminmin freq ] [ -fmaxmax freq ] [ -fintfreq interval  ]  [
     -opbias  ]  [  -trbias  ]  [ -taper% cosine taper ] [ -G ] [
     -minmin polynomial order ] [ -maxmax polynomial  order  ]  [
     -phase ] [ -W ] [ -MEM ] [ -ssam ] [ -V ] [ -? ]


DESCRIPTION

     spec computes amplitude or phase spectra for the input  data
     as  per  the  input  parameters.   The  conventional Fourier
     transform is used (rather than the Fast  Fourier  Transform)
     so  that  the  frequency sample increment can be arbitrarily
     specified. The output is either amplitude or phase. The pro-
     gram  will  also  produce  an amplitude spectrum via Maximum
     Entropy Method.  Note that MEM  does  not  produce  a  phase
     response.   Output data consists of amplitude or phase spec-
     tra in USP format. The user can extract the values and  plot
     with  USP program sis_xy and xgraph.  The sample interval is
     in the output data line header and can be read as Hertz. For
     MEM the last sample of the time series is the  optimum order
     for the polynomial 'best' fitting the spectra.

     spec gets both its data and its parameters from command line
     arguments.   These  arguments specify the input, output, the
     scaling information output file, the optional  1st  spectral
     maxima  output  file,  the start and end records and traces,
     start and end times for windows, frequency end points,  fre-
     quency   increment   ,window   tapering,  phase  unwrapping,
     minimum order of the polynomial and maximum order of a poly-
     nomial when using Maximum Entropy Method, trace bias removal
     and operator bias removal options and verbose  printout,  if
     desired.

  Command line arguments
     -N ntap
          Enter the input data set name or file immediately after
          typing  -N.   If piping in this command line entry will
          be omitted.  The input file should include the complete
          path name if the file resides in a different directory.
          Example -N/b/vsp/dummy tells the program  to  look  for
          file 'dummy' in directory /b/vsp

     -O otap
          Enter the output data  set  name  or  file  immediately
          after  typing -O. This output file is not required when
          piping the output to another process. The  output  data
          set also requires the full path name (see above).

     -S stap
          Enter the scaling output data set name or file  immedi-
          ately  after typing -S. This output is used as input to
          the USP routine scspec to remove the wavelet  overprint
          from the tuning cube.  This is mainly used when import-
          ing the cube to Landmark or  IESX  and  want  the  data
          scaled  in  this  fashion.  If displaying the output in
          xsd use a maximum  scalar  of  1.0  on  your  frequency
          slices  and  you  won't need this applied using scspec.
          Be aware that the maximum spectral ampltiude at a given
          frequency  can  easily  be  coming from a noisy area of
          your tuning cube if appropriate triming of the  dataset
          has  not  been done beforehand to limit edge effects of
          previous processing.

     -F ftap
          Enter the data set name for the statistics of the first
          spectral  maxima  file.   The first sample contains the
          frequency at which the first  spectral  maxima  occurs.
          The  second  sample contains the amplitude at the first
          spectral  maxima.   This  information  is  critical  to
          determining  the maximum frequency useful for thickness
          estimations locally.

     -rs irs
          Enter the start record number.  Default  value  is  the
          first record.

     -re ire
          Enter the end record number.   Default  value  is  last
          record.

     -ns ns
          Enter start trace number.  Default is  first  trace  of
          record.

     -ne ne
          Enter end trace number.  Default value is last trace of
          record.

     -s iwst
          Enter start  time  of  window  for  harmonic  analysis.
          Default is the start of the trace.

     -e iwed
          Enter end of window for harmonic analysis.  Default  is
          end of trace.

     -taper taper
          Enter percent cosine taper to apply to window. 100%  is
          full cosine taper and 0% is no taper.   Default is 10%.

     -G   Enter the command line argument  '-G'  to apply a Gaus-
          sian taper.  This option overrides the cosine taper and
          needs no percent value input.

     -fmin min freq
          Enter  beginning  frequency  for   harmonic   analysis.
          Default is 0 Hz.

     -fmax max freq
          Enter ending frequency for harmonic analysis.   Default
          is Nyquist frequency.

     -fint freq interval
          Enter frequency increment in Hz.  Default is 1 hz.

     -min min polynomial order
          Enter minimum allowable order of the polynomial modeled
          to fit the ME amplitude spectrum.  if -max and -min are
          equal then only that value  is  used  for  all  traces.
          Default is 2.

     -max max polynomial order
          Enter maximum allowable order of the polynomial modeled
          to fit the ME amplitude spectrum.  if -max and -min are
          equal then only that value  is  used  for  all  traces.
          Default is 2.

     -phase
          Enter the command  line  argument  '-phase'  to  output
          phase.  The  analysis window center is the phase refer-
          ence.

     -W   Enter the command line argument  '-W'  to  leave  phase
          wrapped.  The default is to unwrap the phase.

     -MEM Enter the command line argument  '-MEM'  to enable  the
          Maximum  Entropy Method.  The last sample in the output
          is the order polynomial used to calculate  the  spectra
          for that trace.

     -trbias
          Enter the command line argument  '-trbias'   to  remove
          the trace bias prior to decomposition.  This used to be
          the default in this code as  written  by  the  original
          authors.   I  am  not  sure  what they were thinking as
          assumptions of zero mean are really not valid for short
          time series which are often the case with this applica-
          tion.  I believe the notion for this option  came  from
          thinking  about  the  FFT  of  a stationary time series
          where zero mean is an assumption that makes sense.   It
          is  a  dangerous  option  to invoke here however, espe-
          cially if you are  after  thickness  estimates  in  the
          presence of thinning units.  I am leaving this capabil-
          ity as an option in the program purely  for  historical
          reasons.   Also  a  user  may  want  to recreate an old
          result and may need this turned on  for  that  purpose.
          Please be very careful with your analysis and give this
          a lot of theoretical thought if you choose to use  this
          option [Garossino].

     -opbias
          Enter the command line argument '-opbias' to remove the
          operator  bias  during  the  decomposition calculation.
          This, along with the trace bias removal above, used  to
          be  the  default  in  this  routine  [prior to June 28,
          1999].   After  much  thought  and  consultation   with
          Gutowski and Vassiliou I can find no theoretical reason
          for this operation.  It can do nothing but harm to your
          output  thickness  estimates.   I  would  NOT  use this
          option and recommend AGAINST using it.   I  am  leaving
          the  capability as an option merely for historical com-
          pleteness.  A user may need to turn this on to recreate
          an  old  result.   If you choose to try this option you
          may well be faced with explaining what you  think  your
          are doing.

     -ssam
          Enter the command line argument '-ssam' to get a  prin-
          tout  to  stderr  at  the  start of every input record.
          This allows the SSAM user to monitor how  the  applica-
          tion is running.

     -V   Enter the command line argument '-V' to get  additional
          printout.

     -?   Enter the command line argument '-?', -h  or  -help  to
          get online help.  The program terminates after the help
          screen is printed.


DISCUSSION:

     For an excellent primer  on  this  process  point  your  web
     browser to

      http://eptgweb/~usp/TechTransfer/OnlineTraining/Spec_Tutorial/SpecDoc.html




BUGS

     No bugs known at present.


SEE ALSO

     timfreq, freqtim, samps, fk, specal, ampspec, fft2da, fftxy,
     rwspec, mesa


AUTHOR(S):

     [James M. Gridley], with much help from a variety  of  folks
     and in cooperation with Greg Partyka.  Also, Maximum Entropy
     Method was developed by Paul Gutowski.  [Paul G.A. Garossino
     -  June/99], Complete rewrite to move table calculations out
     of the trace loop and make output  compatible  with  rwspec.
     Also  converted  trace  bias  and  operator  bias removal to
     options rather than the default.


COPYRIGHT

     copyright 2001, Amoco Production Company
               All Rights Reserved
          an affiliate of BP America Inc.






































Man(1) output converted with man2html