NAME
upsum - module to do upsum Frequency Determination Panel
SYNOPSIS
upsum [ -Nntap ] [ -rsnrst ] [ -renred ] [ -f1freq1 ] [
-fmaxmaxfreq ]
DESCRIPTION
upsum is a c-shell script which utilizes several USP rou-
tines to construct a upsum panel of the input dataset. It
is recommended that a single record at a time be processed.
The output consists of the input record followed by a set of
bandpass records corresponding to the number of input
filters used, followed by a set of summation records. The
upper frequency of each bandpass and upsum record is con-
tained in the RecNum trace header entry for plotting with
TPLTR. The first bandpass has the following filter points:
f1 = -f1
f2 = -f1 + 5
f3 = -f1 + 10
f4 = -f1 + 15
The number of output bandpass filters is a function of the
-fmax and the above bandpass will have each entry incre-
mented by 10 hertz until the f4 entry becomes greater than
-fmax.
upsum gets both its data and its parameters from command
line arguments. These arguments specify the input, start
and end records, initial f1 frequency and maximum f4 fre-
quency.
Command line arguments
-N ntap [no default]
Enter the input data set name or file immediately after
typing -N This input file should include the complete
path name if the file resides in a different directory.
Example -N/b/vsp/dummy tells the program to look for
file 'dummy' in directory '/b/vsp'.
-rs nrst
Enter start record number. Default value is the first
record.
-re nred
Enter end record number. Default value is last record.
-f1 freq1
Enter the initial f1 frequency. Default value is zero.
-fmax maxfreq
Enter the limiting f4 frequency for the panel. Default
value is 95 hertz.
program terminates after the help screen is printed.
Enter the command line argument 'upsum' to get online help. The
BUGS
unknown
SEE ALSO
downsum(1)
AUTHOR
Paul Garossino
COPYRIGHT
copyright 2001, Amoco Production Company
All Rights Reserved
an affiliate of BP America Inc.
Man(1) output converted with